HRV has become the most widely tracked recovery indicator on smartwatches and smart rings. It does not measure the same thing as heart rate, and it is this difference that makes it useful. Here’s what it tracks, how to measure it accurately, and what it reveals about your nights’ sleep.
Contents
What exactly is HRV?
HRV, or heart rate variability, measures the variations in the time between two successive heartbeats. A healthy heart does not beat like a metronome: it constantly speeds up and slows down. The greater these variations are at rest, the more flexible the nervous system is considered to be.
Both are read by the same sensor and tell two different stories. Heart rate matters how much beats per minute. The HR records the irregularity of the interval between them.
Let’s take a heart beating at sixty beats per minute. Intuitively, that’s one beat every second. In reality, the intervals constantly lengthen and shorten: one second, then nine-tenths, then eight, then nine again. This flexibility is what HRV measures, and a heart that really did beat like a metronome would be a very bad sign.
Three acronyms are in use for the same measure: VFC in French, HRV in English, and RMSSD, the name of the calculation displayed by most devices.
What your heart rate variability reveals about your nervous system
The heart’s rhythm is not determined by the heart alone. It is regulated by the autonomic nervous system – the system that works without you even realising it, and which operates on two levels.
- The friendly branch is the accelerator. It kicks in when under strain, under pressure or in a state of alert, and tends to make the pace more rigid.
- The parasympathetic branch is the brake. It takes over when we are at rest, whilst we are digesting, and especially whilst we are asleep. It is what allows the rhythm to breathe.
HRV is one of the few non-invasive ways of assessing the balance between these two mechanisms. Wide variability at rest is interpreted as a sign that the brake is doing its job; suppressed variability over several consecutive days is interpreted as a sign that the accelerator remains engaged when it should no longer be.
What she doesn’t say, however, is why. A strenuous training session, a short night’s sleep, jet lag, a setback or the onset of a cold can all cause the same dip in energy levels. The indicator alerts you; it does not explain why. The night-time aspect of this mechanism is explained in detail in our article on what happens in the body when you sleep whilst grounded.
How to measure your resting heart rate accurately
VFC is sensitive to protocol. A change in time, position or equipment is enough to produce a deviation greater than the one we were seeking to observe. Three factors are more important than the equipment.
- Always at the same time. The standard is to take your measurement in the morning, upon waking, before getting out of bed and before your first coffee.
- Still in the same position. Lying on your back, or sitting up, but never one and then the other: simply sitting up changes the value.
- Still using the same camera. Two different sensors do not give the same reading for the same night, and the differences between them cannot be converted.
| Time of measurement | Standard equipment | What the measure is worth |
|---|---|---|
| Upon waking, whilst lying down, before getting up | Chest strap, ring, watch | The most consistent from one day to the next. It’s the benchmark |
| Overnight, continuously | Ring, watch, bedding sensor | Averaged over several hours, so less affected by morning fluctuations. Very good for identifying trends |
| During the day, after a workout or a coffee | Any sensor | Unusable for monitoring. Too many factors are at play. |
As for the parameter displayed, the RMSSD is the one used by most consumer devices: it responds mainly to parasympathetic activity and is calculated over a short time window. For personal monitoring, the most useful approach is not to choose the best parameter, but to stick with the one you’ve chosen.
Why a single value means nothing
This is the most common mistake, perpetuated by apps that display a number of the day in large font. There is no single ‘correct’ resting heart rate. The difference between two people of the same age and fitness level can be considerable, even though one is not necessarily in better shape than the other. Comparing your performance with that of a friend provides no useful information.
What makes sense is your own baseline, calculated over several weeks under identical conditions, and the day’s deviation from that figure. Reputable apps work as follows: a seven-day moving average compared with your historical data.
A low night’s sleep is therefore not a signal. A low week is a signal, and a gradual recovery following a period of high sleep demand is the most useful information this indicator can provide. For athletes, this reading is combined with sleep volume, which is discussed in How many hours of sleep does an athlete really need?.
What the CNEA study found, and what it did not show
What was measured, and how. A pilot study was carried out in 2024 at the CREPS CNEA in Font-Romeu with 27 trail runners, following an intense trail running session, with one group wearing the device and the other without. The measurements were taken 48 hours after the exercise, based on objective parameters – muscle strength and resting heart rate – rather than on a self-report questionnaire.
The results, and what they mean. The resting heart rate at 48 hours changes from -7.7 % in the treatment group, compared with +6.9 % in the placebo group. A resting heart rate that drops again after exercise is interpreted as a sign that the parasympathetic brake has regained control – the very trend that HRV tracks. At the muscular level, the group wearing the device had regained 98.6% of its initial strength at 48 hours, as opposed to 95,6 % for the group without the device.
And as for VFC itself, this study does not provide any useful information. The unit hired to measure variability malfunctioned; the readings are unusable, and the report acknowledges this within its own limitations. We are not publishing them. This is frustrating in an article dealing with HRV, and it is precisely what the previous section recommends: a measurement whose protocol has failed is worthless, even if it were to support our case.
The scope. Internal study conducted in 2024, unpublished, involving 27 trail runners, and not yet peer-reviewed. A PhD programme is currently underway at the CNEA until 2028 to formalise this research.
You can check this for yourself. Record your night-time heart rate for thirty nights under stable conditions, change just one setting, and keep it up for another thirty nights. This is the only comparison that matters to you, and all it takes is consistency.
Sleep, passive recovery and HRV
The fact that the baseline measurement is taken upon waking is no mere coincidence in the protocol. Night-time is the period when the parasympathetic nervous system is active for the longest uninterrupted period. Anything that disrupts sleep – such as screen time late at night, heat, noise or mental stress – is reflected in the next morning’s HRV.
This is the basis on which IAKOTA mattress toppers are designed. Their active layer absorbs and then re-emits the infrared radiation that the body is already emitting, in a long strip that does not heat up, and the fabric connects the sleeper to earth via a wall socket. No external power, no batteries, no emissions.
Should we expect the VFC to rise? That would be going beyond what has been established. The hypothesis is formulated in the conditional: if a less disturbed night allows the parasympathetic nervous system to play a greater role, the HRV upon waking should reflect this, and a personal monitoring period of thirty nights is sufficient to confirm or refute this. The set-up is just as important as the product itself, and the actions that matter lie within our instructions for use of the mattress topper.
Frequently asked questions
What is a good heart rate value?
There isn’t one. The variation between individuals is too great for a threshold to be meaningful. The only useful comparison is between your value for today and your own average from previous weeks, measured under the same conditions.
RMSSD or SDNN – which one should you go for?
For daily monitoring using a consumer-grade device, the RMSSD provides a short time window and is particularly sensitive to the parasympathetic component. The SDNN requires longer recordings. The key is not to switch between the two.
Do you need an expensive device?
No. All you need is a chest strap and a free app. Consistency in following the programme is far more important than the price of the sensor.
My heart rate has been dropping for the last three days – should I be worried?
A dip in form lasting a few days is a common occurrence following a period of intense training, a trip or the onset of an infection. If it lasts for several weeks, or if it is accompanied by symptoms, this is something you should discuss with a healthcare professional, not a mobile app.
Can a mattress topper increase heart rate?
That is not what we are claiming, and the study cited above does not support that conclusion: its variability measurement device was faulty. An IAKOTA mattress topper is a wellness product, not a medical device, and its purpose is to promote comfort and recovery.
The three mattress toppers in the Terra range, priced from €249 to €899, are made in France and come with a risk-free trial: 30 days to change your mind, free returns, label provided.